Related Experiment Video
Updated: Jan 30, 2026

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Surface Roughness of Glass Ionomer Cements after Application of Different Polishing Techniques
Ante Miličević1, Kristina Goršeta1, Raimond Nv van Duinen2
1Department of Pedodontics and Preventive Dentistry, School of Dental Medicine University of Zagreb.
Abstract:
Glass Ionomer Cements (GIC) have been widely used in clinical practice since they have a wide range of positive characteristics: chemical bonding to the tooth surface, fluoride release, a heat-expansion coefficient similar to the tooth, do not require an absolutely dry working area, less volumetric contraction, good color stability. Physical properties can be improved by using external energy such as ultrasound and radiant heat (thermo-curing), which also accelerates chemical curing. Objectives: The aim of this study was to determine the most effective polishing technique and to compare the surface roughness of two Glass Ionomer Cements after treatment with heat (thermo-curing), and without heat treatment during the setting process. Materials and methods: Two polishing systems (Tungsten carbide burs and Sof-Lex discs) were used on two types of GIC (Equia Fil and Ketac Molar Universal). Bluephase 16i LED (Vivadent, Schaan Liechtenstein) light was used for the specimens treated with heat (thermo-curing). Samples without heat treatment are left for 10 minutes to chemically cure. Surface profilometar was used for measuring the mean surface roughness value (Ra). Results: Group with Mylar strip (control group) of each material showed the lowest (Ra) value. The Equia Fil material samples treated with heat (thermo-curing) achieved lower surface roughness values (Ra), and showed lower surface roughness values (Ra) after polishing with a Sof-Lex discs (p<0.05). The results for Ketac Molar Universal samples showed no statistically significant difference (p>0.05) between polishing with Sof-Lex discs and Tungsten carbide burs. Conclusion: Based on the obtained results, it can be concluded that the smoothest surface roughness is achieved by the Mylar strip. Some types of Glass Ionomer Cements can obtain better surface polishing with heat treatment (thermo-curing).
Related Concept Videos
Hydration of Cement
Soundness of Cement
The Looking Glass Self
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...