Related Experiment Video
Updated: Jan 30, 2026

Automated Segmentation of Cortical Grey Matter from T1-Weighted MRI Images
Published on: January 7, 2019
Post-contrast T1-weighted spine 3T MRI in children using a golden-angle radial acquisition
Houchun H Hu1, Thomas Benkert2, Mark Smith3
1Department of Radiology, Nationwide Children's Hospital, 700 Children's Drive, Columbus, OH, USA. houchun.hu@nationwidechildrens.org.
Purpose:
MRI methods that have reduced sensitivity to motion are attractive in pediatric applications. In spine imaging, physiologic motion such as respiration and cerebrospinal fluid pulsation can hamper diagnostic image quality. We compare a 3D T1-weighted non-Cartesian radial acquisition with a conventional Cartesian 2D turbo-spin-echo (TSE) acquisition in axial post-contrast spine imaging at 3T.
Methods:
Thirty-two patients (mean age 12.2 ± 5.3 years) scheduled for routine clinical spine exams with contrast were enrolled. Three pediatric neuroradiologists compared the two sequences and assessed the presence of motion, the conspicuity of nerve roots, and whether one of the sequences was preferred in visualizing pathology using Likert scales.
Results:
The Fleiss' kappa statistic for inter-rater agreement was 0.29 (95% confidence interval, 0.15-0.43) for the presence of motion, 0.30 (0.21-0.38) for conspicuity, and 0.37 (0.19-0.55) for sequence preference. Radial images were less sensitive to motion than TSE (p < 0.01). Motion and consequent artifacts were present in all TSE cases, while it was absent in 51% of the radial cases. In depicting nerve roots, radial images were superior in the cervical (p < 0.05), thoracic (p < 0.01), and lumbar spines (p < 0.01). Lastly, in 28 of the 32 patients who demonstrated contrast-enhancing pathology, radial images were preferred in 51% of the cases, while both sequences were equally preferred in 41% of the cases.
Conclusion:
We demonstrate the potential utility of radial MRI in post-contrast spine imaging. The free-breathing method is robust in generating diagnostic image quality and is superior in visualizing nerve roots and extramedullary metastases than traditional Cartesian TSE acquisitions.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Light Acquisition
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

