Related Experiment Video
Updated: Jan 30, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Comparing phase- and amplitude-gated volumetric modulated arc therapy for stereotactic body radiation therapy using
Minsik Lee1, KyoungJun Yoon1, Byungchul Cho1
1Departments of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Purpose:
To compare the dosimetric impact and treatment delivery efficacy of phase-gated volumetric modulated arc therapy (VMAT) vs amplitude-gated VMAT for stereotactic body radiation therapy (SBRT) for lung cancer by using realistic three-dimensional-printed phantoms.
Methods:
Four patient-specific moving lung phantoms that closely simulate the heterogeneity of lung tissue and breathing patterns were fabricated with four planning computed tomography (CT) images for lung SBRT cases. The phantoms were designed to be bisected for the measurement of two-dimensional dose distributions by using EBT3 dosimetry film. The dosimetric accuracy of treatment under respiratory motion was analyzed with the gamma index (2%/1 mm) between the plan dose and film dose measured under phase- and amplitude-gated VMAT. For the validation of the direct usage of the real-time position management (RPM) data for respiratory motion, the relationship between the RPM signal and the diaphragm position was measured by four-dimensional CT. By using data recorded during the beam delivery of both phase- and amplitude-gated VMAT, the total time intervals were compared for each treatment mode.
Results:
Film dosimetry showed a 5.2 ± 4.2% difference of gamma passing rate (2%/1 mm) on average between the phase- vs amplitude-gated VMAT [77.7% (72.7%-85.9%) for the phase mode and 82.9% (81.4%-86.2%) for the amplitude mode]. For delivery efficiency, frequent interruptions were observed during the phase-gated VMAT, which stopped the beam delivery and required a certain amount of time before resuming the beam. This abnormality in phase-gated VMAT caused a prolonged treatment delivery time of 366 s compared with 183 s for amplitude-gated VMAT.
Conclusions:
Considering the dosimetric accuracy and delivery efficacy between the gating methods, amplitude mode is superior to phase mode for gated VMAT treatment.
Related Concept Videos
Gene Therapy
Drug Administration and Therapy Phases: Overview
The pharmaceutical phase focuses on leveraging the physicochemical properties of the drug to design and manufacture an effective product. Variants include orally administered tablets or capsules, topical creams or ointments, and parenteral-delivery solutions or emulsions.
The pharmacokinetic phase...
Group Therapy
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Behavior Therapy
Exposure therapy is a cornerstone of behavioral treatment for anxiety disorders. It involves systematic exposure to feared stimuli, either in real...
Drug Therapy
Antianxiety Medications