Related Experiment Video
Updated: Jan 30, 2026

Influence of Step-Width Manipulation on Running Biomechanics
Published on: February 28, 2025
The effect of transfixation pins on the biomechanical properties of angled acrylic connecting bars
Xavier Montasell1, Gregory Herndon1, David Szwec1
1Faculty of Veterinary Medicine, Ringgold Standard Institution - Clinical Sciences, University of Montreal, Saint Hyacinthe, Quebec (Montasell, Herndon, Szwec); Faculty of Veterinary Medicine, University of Montreal, Saint Hyacinthe, Quebec (Beauchamp).
Abstract:
With acrylic external-fixation frames for fracture repair the acrylic columns can be contoured to allow greater versatility in the placement of transfixation pins, thus minimizing damage to the surrounding soft tissue and making mandibular and transarticular fixation easier. However, contouring affects the stiffness and ultimate strength of the construct under axial compression. In this study, polymethylmethacrylate columns 21 mm in diameter angled at 0°, 30°, 45°, 60°, or 90° with clamps were constructed. For each angulation group, pins 3.2-mm long were placed in 6 columns, 2 pins at each end, 1.5 cm from each other, and 6 columns had no pins. Each column was allowed to polymerize for a minimum of 10 min, then was placed in a biomechanical-testing machine, the load cell at the bottom end of the column and the actuator on top, with a preload of 10 to 12 N to prevent slippage. The columns underwent axial loading at a rate of 8 mm/s until catastrophic failure occurred. Data on force and deformation were collected every 0.025 s. Both stiffness and ultimate strength of the column decreased significantly (P < 0.01), up to 77% and 70%, respectively, with each increase of angulation. The columns with pins were significantly less stiff (P < 0.05) than those without pins at angulations of 45° and 60°. However, the columns with pins did not show significant differences in ultimate strength from the columns without pins at any of the angulations. The point of failure was always at the angle of the column, demonstrating that in axial compression the weakest point is not the pin-acrylic interface when pins are eccentrically located within the column.
Related Concept Videos
Bar Graph
Multiple Bar Graph
Each bar or column in the multiple bar graph represents a data value. These graphs are used primarily in interrelating two or more sets of data. The categories of different kinds of data are listed along the horizontal or x-axis, whereas...
Euler's Formula for Pin-Ended Columns
To calculate the critical load, envision...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Dietary Connections

