Abstract:
The selective and sensitive determination of potential genotoxic methanesulfonate impurities in drug substances is highly challenging. A new method is reported for testing of methyl methanesulfonate (MMS), ethyl methanesulfonate (EMS) and isopropyl methanesulfonate (IPMS) in active pharmaceutical ingredients (APIs). Headspace single drop microextraction (HS-SDME) with room-temperature ionic liquid (RTIL) as extractant was employed to preconcentrate analytes and eliminate the drug matrix simultaneously. In order to increase volatilities for HS extraction and to improve their reactivity of the further derivatization at the same time, sodium iodide (NaI) was added to the sample to derivatize methanesulfonates to the corresponding iodoalkanes. The iodoalkanes in the extract were derivatized with N, N-diethyldithiocarbamate (DDTC) after HS-SDME, followed by separation and detection with high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Several important parameters, including reaction temperature, reaction time and concentration of NaI, sample volume, microdrop volume, stirring rate, salt addition, extraction time, concentration, reaction time and reaction temperature of DDTC were investigated. Under the optimal conditions, LODs and LOQs of all methanesulfonates were 15 ng mL-1 and 40 ng mL-1, respectively. Linearity (correlation coefficient values r > 0.999) and precision (the relative standard deviations were 1.0-4.6%) of six repeated injections were obtained. The recoveries at three spiked concentration levels were all in the range of 86.2-107.5% with the relative standard deviations <3.5%. The method reported here avoids interference of drug substances efficiently and detects methanesulfonate impurities in high sensitivity by HPLC-UV in Imatinib Mesylate and Levofloxacin Mesylate.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Drug Product Performance: In Vitro–In Vivo Correlation
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...