Related Experiment Video
Updated: Jan 30, 2026

Experimental Manipulation of Body Size to Estimate Morphological Scaling Relationships in Drosophila
Published on: October 1, 2011
The accuracy of 3D virtual bone models of the pelvis for morphological sex estimation
Kerri L Colman1, Alie E van der Merwe2, Kyra E Stull3,4
1Department of Medical Biology, Section Clinical Anatomy and Embryology, Amsterdam UMC, location AMC, University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands. k.l.colman@amc.uva.nl.
Abstract:
It is currently unknown whether morphological sex estimation traits are accurately portrayed on virtual bone models, and this hampers the use of virtual bone models as an alternative source of contemporary skeletal reference data. This study determines whether commonly used morphological sex estimation traits can be accurately scored on virtual 3D pelvic bone elements. Twenty-seven intact cadavers from the body donation program of the Amsterdam UMC, University of Amsterdam, were CT scanned; this data was used to produce virtual bone models. Thereafter, the dry bones were obtained. Three traits by Klales (2012) and five traits from the Workshop of European Anthropologists (WEA) (1980) were scored on the virtual bone models and their dry skeletal counterparts. Intra- and inter-observer agreement and the agreement between the scores for each virtual bone model-dry bone pair were calculated using weighted Cohen's kappa (K). For all Klales (2012) traits, intra- and inter-observer agreement was substantial to almost perfect for the virtual- and dry bones (K = 0.62-0.90). The agreement in scores in the virtual-dry bone pairs ranged from moderate to almost perfect (K = 0.58-0.82). For the WEA (1980) traits, intra-observer agreement was substantial to almost perfect (K = 0.64-0.91), but results were less unambiguous for inter-observer agreement (K = 0.24-0.88). Comparison of the scores between the virtual bone models and the dry bones yielded kappa values of 0.42-0.87. On one hand, clinical CT data is a promising source for contemporary forensic anthropological reference data, but the interchangeability of forensic anthropological methods between virtual bone models and dry skeletal elements needs to be tested further.
Related Concept Videos
Improving Translational Accuracy
Veins of the Abdomen and Pelvis
The inferior vena cava is fed by numerous smaller veins. The lumbar veins, for instance, drain the posterior abdominal wall, emptying both directly into the inferior vena cava and into the...
Uncertainty in Measurement: Accuracy and Precision
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Sex-linked Disorders
Accuracy and Precision