Challenges in diagnosing Zika-experiences from a reference laboratory in a non-endemic setting
Dorien Van den Bossche1, Johan Michiels2, Lieselotte Cnops3
1National Reference Center for Arboviruses, Department of Clinical Sciences, Institute of Tropical Medicine, Kronenburgstraat 43/3, Antwerp, Belgium. dvandenbossche@itg.be.
Abstract:
Diagnosing a patient with Zika infection is not always straightforward. Here, we aim to describe our data collected from December 2015 to December 2017 and discuss the implemented algorithm and diagnostic challenges we encountered. At the National Reference Center for Arboviruses at the Institute of Tropical Medicine, Antwerp, Belgium (ITM), a commercial Zika virus (ZIKV) enzyme-linked immunosorbent assay (ELISA) detecting immunoglobulin (Ig) M and IgG, a commercial ZIKV immunofluorescence assay (IFA) detecting IgM, and an in-house Zika virus neutralization test (VNT) were implemented. For molecular detection of ZIKV, an in-house and a commercial real-time RT-PCR were applied. An algorithm, adapted from the European Centre for Disease Control and Prevention (ECDC), was implemented. Between December 2015 and December 2017, we tested 6417 patients for ZIKV. Of those, according to ECDC criteria, 127 (2.0%) were classified as a confirmed Zika infection of which 39 by RT-PCR (0.6%), 15 (0.2%) as a probable Zika infection, 73 (1.1%) as undefined, and 65 (1.0%) as false positive reactions. Main challenges were the brief window for detection of IgM, cross-reactivity of antibodies with other flaviviruses and malaria, and low VNT titers in the acute phase. In RT-PCR negative samples, classification of ZIKV infection as recent or past proved difficult, when IgM was negative. The majority of patients could be classified according to ECDC criteria, though 1.1% of patients remained "undefined" and 1.0% were ELISA false positive reactions. Complementary IFA IgM was of added value to increase IgM detection rates. Improved serological assays and more longitudinal data on antibody kinetics are needed.
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Inertial Frames of Reference
Non-inertial Frames of Reference
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
What is an Experiment?
Setting Time of Cement