Related Experiment Video
Updated: Jan 30, 2026

Author Spotlight: Visualizing Olfactory Receptor Expression in Mosquitoes
Published on: November 17, 2023
Signal-on electrochemiluminescence aptasensor for bisphenol A based on hybridization chain reaction and
Huifang Zhang1, Fang Luo2, Peilong Wang3
1MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Institute of Nanomedicine and Nanobiosensing, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China; School of Chemistry and Chemical Engineering, Key Laboratory of Organo-pharmaceutical Chemistry of Jiangxi Province, Gannan Normal University, Ganzhou, 341000, P.R. China.
Abstract:
A simple and sensitive electrochemiluminescence (ECL) aptasensor has been developed for bisphenol A (BPA) detection. The capture DNA (CDNA) was modified on the heated indium-tin-oxide (ITO) working electrode surface firstly and then hybridized with BPA aptamer to form double strand DNA (dsDNA). The presence of target can cause the releasing of aptamer from the electrode surface since the aptamer prefers to switch its configuration to combine with BPA. Subsequently, the free CDNA will induce hybridization chain reaction (HCR) to produce long dsDNA on the electrode surface. Ru(phen)32+ can integrate into the grooves of dsDNA to act as an ECL reagent, thus enhanced ECL signal can be detected. The temperature control during the processes of target recognition and HCR were realized through the heated electrode instead of the bulk solution heating. Furthermore, the performance of the ECL aptasensor can be further enhanced at elevated electrode temperature. Under the optimized conditions, the ECL intensity of the system has a linear relationship with the logarithm of BPA concentration in the range of 2.0 pM-50 nM. The limit of detection (LOD) at 55 °C (electrode surface temperature) was calculated to be 1.5 pM, which was approximately 6.5-fold lower than that at 25 °C. The proposed biosensor has been applied to detect the BPA in drink samples with satisfactory results.
More Related Videos
07:47Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
Published on: September 9, 2025
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
Related Concept Videos
Enthalpy and Heat of Reaction
Free-Radical Chain Reaction and Polymerization of Alkenes
Acids, Bases and Neutralization Reactions
Acids, Bases and Neutralization Reactions
Standard Electrode Potentials
Hybrid Zones