Baseline Assessment for the Consistency of Raman Shifts Acquired with 26 Different Raman Systems and Necessity of a
Nobuyasu Itoh1, Katsuhiro Shirono1, Toshiyuki Fujimoto1
1National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST).
Abstract:
Although Raman shifts originate from molecular vibrations and in theory must be independent of analytical systems, acquired Raman shifts, in practice, are not so. Since the consistency of Raman shifts acquired with different systems has not been investigated previously, we have compared the Raman spectra of polystyrene, benzonitrile, and cyclohexane obtained with 26 different systems. The medians of 26 measurements for the characteristic peaks were found to be 1001.3, 1001.1, and 802.0 cm-1 for polystyrene, benzonitrile, and cyclohexane, respectively, and were consistent with their corresponding ASTM E1840 values, which have been widely used for the calibration of Raman systems. However, only 16 measurements of the Raman shift of the polystyrene peak (1001.4 cm-1) met the tolerance standard of the European Pharmacopoeia (±1.5 cm-1). Thus, consistency of Raman shifts obtained using different systems is low, and this mainly originates from differences in the Raman systems rather than materials. Although correction of the offset using the Raman shift of the peaks of cyclohexane (802.0 or 2852.4 cm-1) could improve the consistency of the Raman shifts acquired with different systems, the magnitude of improvement was not uniform over the range of shift values. Thus, there is a need for a standardized calibration protocol that can be used for multiple Raman shifts of common materials to improve the consistency of Raman shifts for different systems.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Measurement: Standard Units
Standard Electrode Potentials