Related Experiment Video
Updated: Jan 30, 2026

Author Spotlight: Advancing Cancer Associated Thrombosis Research in Rodent Models
Published on: January 5, 2024
Detection of Thromboembolic Events and Pump Thrombosis in HeartWare HVAD Using Accelerometer in a Porcine Model
Itai Schalit1,2, Andreas Espinoza3, Fred-Johan Pettersen4
1From the Intervention Centre, Oslo University Hospital, Oslo, Norway.
Abstract:
We have recently demonstrated that accelerometer-based pump thrombosis and thromboembolic events detection is feasible in vitro. This article focuses on detection of these conditions in vivo. In an open-chest porcine model (n = 7), an accelerometer was attached to the pump casing of an implanted HeartWare HVAD. Pump vibration was analyzed by Fast Fourier Transform of the accelerometer signals, and the spectrogram third harmonic amplitude quantified and compared with pump power. Interventions included injection of thrombi into the left atrium (sized 0.3-0.4 ml, total n = 35) and control interventions; pump speed change, graft obstruction, and saline bolus injections (total n = 47). Graft flow to cardiac output ratio was used to estimate the expected number of thrombi passing through the pump. Sensitivity/specificity was assessed by receiver operating characteristic curve. Graft flow to cardiac output ratio averaged 66%. Twenty-six of 35 (74%) thrombi caused notable accelerometer signal change. Accelerometer third harmonic amplitude was significantly increased in thromboembolic interventions compared with control interventions, 64.5 (interquartile range [IQR]: 18.8-107.1) and 5.45 (IQR: 4.2-6.6), respectively (p < 0.01). The corresponding difference in pump power was 3 W (IQR: 2.9-3.3) and 2.8 W (IQR: 2.4-2.9), respectively (p < 0.01). Sensitivity/specificity of the accelerometer and pump power to detect thromboembolic events was 0.74/1.00 (area under the curve [AUC]: 0.956) and 0.40/1.00 (AUC: 0.759), respectively. Persistent high third harmonic amplitude was evident at end of all experiments, and pump thrombosis was confirmed by visual inspection. The findings demonstrate that accelerometer-based detection of thromboembolic events and pump thrombosis is feasible in vivo and that the method is superior to detection based on pump power.
Related Concept Videos
Venous Thrombosis I: Introduction
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Integration of Synaptic Events