Related Experiment Video
Updated: Jan 30, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Optimal threshold of three-dimensional echocardiographic fully automated software for quantification of left
Victor Chien-Chia Wu1,2, Tetuji Kitano3, Yosuke Nabeshima3
1Department of Laboratory and Transfusion Medicine, University of Occupational and Environmental Health Hospital, Kitakyushu, Japan.
Aims:
Novel fully automated left chamber quantification software for three-dimensional echocardiography (3DE) has a potential for reliable measurement of left ventricular (LV) volumes and ejection fraction (LVEF). However, the optimal setting of global LV endocardial border threshold has not been settled.
Methods And Results:
We performed LV volumes and LVEF analysis using fully automated left chamber quantification software (Dynamic HeartModelA.I., Philips Medical Systems) in 65 patients who had undergone both 3DE and cardiac magnetic resonance (CMR) examinations on the same day. We recorded LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) according to the change in LV global border threshold settings from 0-point to 100-point with each increment of 10-point. These values were compared to the corresponding values of CMR with disk-area summation method and feature tracking (FT) method. Coverage probability (CP) was calculated as an index of accuracy and reliability. Fully automated software provided LV volumes and LVEF in 57 patients (Feasibility: 88%). LVEDV and LVESV increased steadily according to the increase in border threshold and reached minimal bias when border threshold setting was 80 against CMR disk-summation method and 90 against CMR FT method. Corresponding CP of LVEF was 0.74 and 0.84 against disk-area summation method and FT method.
Conclusions:
With CMR values as a reference, LV endocardial border threshold value can be set around 80 to 90 with the same number of LV end-diastole and end-systole threshold to approximate LVEDV, LVESV and LVEF with clinically acceptable CP values of LVEF.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Summation Notation
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance