Comparison of micro-computed tomography and histomorphometry in the measurement of bone-implant contact ratios
Jung-Yoo Choi1, Jae-Il Park2, Ji Soo Chae3
1Dental Research Institute, Seoul National University, Seoul, Korea.
Objective:
The purpose of this study was to measure the 3-dimensional (3D) bone-to-implant contact (BIC) ratios calculated with an associated software algorithm on 3D micro-computed tomography (μCT) scans and compare them with measurements made with 2-dimensional histomorphometry.
Study Design:
For uncomplicated calculation of the 3D BIC ratios, 16 implants (8 grade 2 titanium and 8 grade 4 titanium) with simple cylindrical geometry were inserted into 8 rabbit tibiae; 2 implants were inserted into each tibia. The experimental animals were sacrificed at 2 weeks after surgery. The implants were surgically removed en bloc with surrounding bone. 3D μCT images were acquired and reconstructed, and histomorphometric procedures were performed. The calculated 3D BIC ratios were compared with the histomorphometrically measured BIC ratios.
Results:
When the 3D BIC ratios calculated in this study were compared with the BIC ratios measured conventionally by using histologic slides for light microscopy, no significant statistical correlation was found between the 2 ratios (P ≥ .35).
Conclusions:
This study indicated that 3D μCT should be used for more accurate BIC assessment to produce an overall 3D picture for the bone-implant interface.
More Related Videos
04:24Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography
Published on: November 22, 2017
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Imaging Studies III: Computed Tomography
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
The Sense of Self: Reflected Self-Appraisal and Social Comparison