Related Experiment Video
Updated: Jan 30, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
[Direct determination of ultra-trace polycyclic aromatic hydrocarbons in water by liquid chromatography coupled with
Chao Wang1, Zhaozhang Huang2, Zhanlei Xing3
1China National Environmental Monitoring Centre, Beijing 100012, China.
Abstract:
A method was developed for the direct determination of 16 ultra-trace polycyclic aromatic hydrocarbons (PAHs) in water by liquid chromatography (LC) coupled with online solid phase extraction (online SPE). The water sample was centrifuged at a high speed to remove the particulate matter and prepared into an aqueous solution containing 40% (v/v) methanol. A 2 mL-sample was directly injected into the online SPE flow path. Online purification and enrichment of the samples were carried out on the SPE column (Acclaim PA Ⅱ, 50 mm×4.6 mm, 3 μm). The PAHs eluted from the SPE column were transferred to the analytical flow path by valve switching, and were separated on a Hypersil Green PAHs column (150 mm×3 mm, 3 μm). Water and acetonitrile were used as the mobile phases. The flow rates of 1.0 mL/min and 0.4 mL/min were used in the extraction and balance processes, respectively. The flow rate of 0.6 mL/min was used to separate the PAHs in the analytical flow path. Acenaphthylene without a fluorescent signal was detected at the ultraviolet absorption wavelength of 220 nm, while other PAHs were measured by the fluorescence signal via the special excitation/emission wavelength program. The entire analysis could be completed within 37 min. The linear correlation coefficients of the 16 PAHs were greater than 0.996. The limits of detection of the PAHs were 0.14-12.50 ng/L (S/N=3) with only 0.38 ng/L for benzo(a)pyrene (B(a)P). The recoveries of PAHs at spiked levels of 10, 40 and 200 ng/L in the water samples were 76.1%-134.9%. The RSDs (n=3) were 0.3%-16.6%. Furthermore, the recoveries and RSDs (n=3) of B(a)P were 71.8%-92.7% and 3.9%, respectively. The proposed method is simple, rapid, solvent-saving, stable and sensitive, and can meet the ultra-trace analysis requirements of the PAHs (especially B(a)P) in various water samples.
More Related Videos
Related Concept Videos
Aromatic Hydrocarbon Anions: Structural Overview
Due to the absence of continuous...
Aromatic Hydrocarbon Cations: Structural Overview
Removing one hydrogen from the intervening CH2 group...
Molecular Comparison of Gases, Liquids, and Solids
Speed of Sound in Solids and Liquids
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:

