Related Experiment Video
Updated: Jan 30, 2026

A Decellularization Methodology for the Production of a Natural Acellular Intestinal Matrix
Published on: October 7, 2013
Passot-Type Immediate Breast Reconstruction Obviates the Use of Aceullular Dermal Matrix in Grades 2 and 3 Ptosis
Joshua J Rivet1, Kristopher M Day, Jeffrey F Rau
1From the Department of Plastic Surgery, University of Tennessee College of Medicine, Chattanooga, TN.
Purpose:
Acellular dermal matrices (ADMs) are commonly used for immediate breast reconstruction after skin-sparing mastectomy (SSM). Regnault grades 2 and 3 ptotic breasts feature significant mastectomy flap redundancy that may be incorporated into the reconstruction. This allows surgeons to use patients' de-epithelialized inferior dermal pedicle instead of ADM.
Methods:
All consecutive SSM patients with Regnault grade 2 or 3 ptosis who underwent Passot-type immediate breast reconstruction (IBBR) with tissue expanders (TEs) and de-epithelialized inferior dermal pedicle without an ADM were included. Patient data from the electronic medical record, clinical photographs, and a comparative cost analysis of ADM versus additional operative time are provided.
Results:
Thirty-eight patients with an average age of 52.7 years, weight 210.5 lb, and body mass index of 35.1 kg/m were treated (34 bilateral, 4 unilateral; 72 reconstructed breasts). Average mastectomy specimens weighed 962.8 g. Tissue expanders were filled to 265.0 mL (41.6% capacity) intraoperatively, and final implant volume averaged 710.9 ± 118.5 mL after an average of 628.6 ± 74.1-mL expansion. Operative times for Passot-type IBBR was 124.3 ± 37.7 versus 92.5 ± 27.9 minutes (P = 0.0001) for submuscular TE placement with ADM. The operative technique is described in detail. There were 8 TE explantations (21.1%) included: intractable infection (10.5%; n = 4), symptomatic capsular contracture (7.9%; n = 3), and spontaneous TE deflation (2.6%; n = 1). All but 3 patients (92.1%) successfully completed Passot reconstruction, with 2 patients declining salvage latissimus dorsi flap reconstruction and 1 patient lost to follow-up. Total cost savings in this case series was $89,724 ($2361 ± $3529/case).
Conclusions:
Additional prospective comparison studies are needed to determine whether Passot-type IBBR results in higher complication rates than conventional IBBR with ADM in this challenging patient population. Passot-type IBR after SSM is safe, demonstrates acceptable rates of successful breast reconstruction, confers cost savings by obviating the use of ADM, and provides favorable aesthetic results.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
04:41Author Spotlight: Analysis of Ovarian Anatomy in Migratory Insects to Overcome Experimental Challenges
Published on: July 14, 2023
Related Concept Videos
Types of Aggregate Grading
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3
Diabetes Mellitus: Type 2 and Gestational
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
The Extracellular Matrix
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...