Related Experiment Video
Updated: Jan 30, 2026

07:11
Author Spotlight: Insights into Visual Cortex Research Through Wide-View fMRI Mapping
Published on: December 8, 2023
2.4K
Radially arranged dihedral corner reflector array for wide viewing angle of floating image without virtual image
Optics Express
|January 31, 2019
Summary
A new radially arranged dihedral corner reflector array (DCRA) creates wide-angle, floating 3D images without virtual images. This innovative design expands viewing angles significantly compared to conventional DCRAs.
Area of Science:
- Optics and Photonics
- Display Technology
Background:
- Dihedral corner reflector arrays (DCRAs) are used in optical systems.
- Conventional DCRAs can produce virtual images and have limited viewing angles.
Purpose of the Study:
- To propose and evaluate a novel radially arranged DCRA.
- To achieve a floating, three-dimensional image with a wide viewing angle.
- To eliminate virtual image formation.
Main Methods:
- Designed a specific reflector array pattern for the radially arranged DCRA.
- Measured the reflection ratio of the proposed array.
- Evaluated the viewing angle of the displayed floating image.
Main Results:
- The radially arranged DCRA successfully displayed a floating image.
- The viewing angle was expanded from ±30° to ±90°.
- No virtual images were produced.
Conclusions:
- The radially arranged DCRA offers a significant improvement over conventional DCRAs.
- This technology enables wider viewing angles for 3D floating image displays.
- The design effectively prevents the formation of unwanted virtual images.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
414
This lesson explores three gastrointestinal imaging techniques: radionuclide testing, colonic transit studies, and virtual colonoscopy.
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
414
Fascicle Arrangement in Skeletal Muscles
3.9K
Fascicles are bundles of muscle fibers in a skeletal muscle. Muscle fascicle arrangement is directly associated with the power and range of motion of various muscles. The configuration of these fascicles can vary, leading to different functional outcomes.
The four primary types of muscle based on fascicle arrangement are:
The four primary types of muscle based on fascicle arrangement are:
3.9K
Radial System Protection
439
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
439
Virtual Work
1.4K
The principle of virtual work states that if a body is in static and dynamic equilibrium, then the sum of all the virtual work done by all external forces and couple moments for any given virtual displacement must be zero.
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
1.4K
Contact Angle
19.2K
When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
19.2K
Imaging Studies VII: Vascular Imaging
367
DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...
367

