Related Experiment Video
Updated: Jan 30, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Metropolis Monte Carlo simulation scheme for fast scattered X-ray photon calculation in CT
Abstract:
Monte Carlo (MC) method is commonly considered as the most accurate approach for particle transport simulation because of its capability to precisely model physics interactions and simulation geometry. Conventionally, MC simulation is performed in a particle-by-particle fashion. In certain problems such as computing scattered X-ray photon signal at a detector of CT, the conventional simulation scheme suffers from low efficiency mainly due to the fact that abundant photons are simulated but do not reach the detector. The computational resources spent on those photons are therefore wasted. To solve this problem, this study develops a novel GPU-based Metropolis MC (gMMC) with a novel path-by-path simulation scheme and demonstrates its effectiveness in an example problem of scattered X-ray photon calculation in CT. In contrast to the conventional MC approach, gMMC samples an entire photon path extending from the X-ray source to the detector using Metropolis-Hasting algorithm. The path-by-path simulation scheme ensures contribution of every sampled event to the signal of interest, improving overall efficiency. We benchmark gMMC against an in-house developed GPU-based MC tool, gMCDRR, which performs simulations in the conventional particle-by-particle fashion. gMMC reaches speed up factors of 37~48 times in simple phantom cases and 20-34 times in real patient cases. The results calculated by gMCDRR and gMMC agree well with average differences < 3%.
More Related Videos
07:55Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
09:15Combining X-Ray Crystallography with Small Angle X-Ray Scattering to Model Unstructured Regions of Nsa1 from S. Cerevisiae
Published on: January 10, 2018
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
The Z-Scheme of Electron Transport in Photosynthesis
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Standard Free Energy Changes
Calculating pH Changes in a Buffer Solution