A Quantitative Comparison of Clinically Employed Parameters in the Assessment of Acute Cerebral Ischemia Using

Christian Nasel1,2,3, Uros Klickovic2,4, Heike-Marie Kührer2

  • 1Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.

Frontiers in Physiology
|January 31, 2019
PubMed

Insights

Standardized time-to-peak (stdTTP) and zf-score offer more consistent perfusion assessment in acute ischemic stroke than traditional Tmax. These parameter-free methods improve infarct volume estimation, aiding therapy decisions.

Area of Science:

  • Neuroimaging
  • Radiology
  • Stroke Medicine

Background:

  • Perfusion magnetic resonance imaging (P-MRI) is crucial for acute ischemic stroke therapy decisions.
  • Dynamic susceptibility contrast (DSC) MRI's time-to-maximum (Tmax) parameter is widely used but subject to bias from inconsistent computation and arterial input function (AIF) selection.
  • Parameter-free methods like standardized time-to-peak (stdTTP), zf-score, and standardized-zf (stdZ) offer consistent calculations without AIF or deconvolution.

Purpose of the Study:

  • To compare the robustness of infarct volume estimation using Tmax against parameter-free methods (stdTTP, zf-, stdZ).
  • To evaluate the performance of different perfusion parameters across varying MRI acquisition parameters and sites.

Main Methods:

  • Compared Tmax with stdTTP, zf-, and stdZ in 66 acute ischemic stroke patients.
  • Utilized data from two sites with different MRI systems (1.5T vs. 3T) and acquisition parameters (TR, bolus dose).
  • Assessed parameter performance using quality factors (QF) for sensitivity, specificity, accuracy, and Receiver Operating Characteristic (ROC) analysis.

Main Results:

  • stdTTP demonstrated the highest specificity (0.93 ± 0.05) and accuracy (0.90 ± 0.04), with sensitivity of 0.56 ± 0.17.
  • zf-score showed the highest sensitivity (0.72 ± 0.16), while other parameters performed comparably to Tmax.
  • ROC analysis revealed stdTTP and zf-score as the best predictors of final infarct volume, with stdTTP showing significantly higher predictive power (odds ratio = 6.42).

Conclusions:

  • Parameter-free methods, particularly stdTTP and zf-score, provide more consistent and robust infarct volume estimation in acute ischemic stroke.
  • Reanalysis of large cohort studies using these parameters is recommended to enhance the consistency of perfusion assessment.
  • These findings support the adoption of stdTTP and zf-score for improved clinical decision-making in acute stroke management.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.4K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
275
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Acute Pancreatitis II: Clinical Manifestations and Management01:30

Acute Pancreatitis II: Clinical Manifestations and Management

Acute pancreatitis presents a complex medical emergency characterized by rapid onset inflammation of the pancreas, demanding timely diagnosis and management to prevent complications. The condition primarily manifests through severe upper abdominal pain that often radiates to the back. This pain intensifies following the consumption of fatty foods. Accompanying symptoms such as nausea, vomiting, abdominal distention, fever, dyspnea, cyanosis, and jaundice can vary in intensity but significantly...
846
Nuclear Magnetic Resonance (NMR): Overview01:07

Nuclear Magnetic Resonance (NMR): Overview

Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.9K