Comparison of digital protocols for the measurement of peri-implant marginal bone loss
David Peñarrocha-Oltra1, Ivan Palau2, Guillermo Cabanes3
1DDS, PhD. Assistant Professor of Oral Surgery and Implantology. University of Valencia Medical and Dental School.
Background:
The measurement of peri-implant marginal bone loss is currently carried out using digital methods of radiographic analysis assisted by various types of software. The purpose of this study was to compare the characteristics of three different softwares: specific radiology software for the development and visualization of radiological images in DICOM format (3Dicom Viewer®), advanced level software for professional editing of bitmap images (or raster graphics) (Adobe Photoshop®), and mid-level software for processing bitmap-type images, programmed in Java and in the public domain (ImageJ®).
Material And Methods:
It was verified that the three softwares used are valid for the measurement of peri-implant marginal bone loss provided that the appropriate protocol is fulfilled.
Results:
The results showed no significant differences between Adobe Photoshop® and ImageJ® with respect to 3Dicom Viewer® in the measurements of mesial and distal bone loss of the implants, without influence of the dental sector where they were located.
Conclusions:
The measurements made with ImageJ® looked more like those of the control software (3Dicom Viewer®) than those of Adobe Photoshop®, but with a greater degree of dispersion. Thus, Adobe Photoshop® is a slightly inaccurate method but with less dispersion. Key words:Digital measurement, measurement software, peri-implant marginal bone loss, implants.
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Margin of Error
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...