Percutaneous Biventricular Mechanical Circulatory Support With Impella CP and Protek Duo Plus TandemHeart
Nachiket J Patel1, Divya R Verma, Radha Gopalan
1Banner University Medical Center, 1111 East McDowell Rd, Phoenix, AZ 85006 USA. nachiketjpatel@gmail.com.
Abstract:
This is the first reported case of full biventricular mechanical circulatory support with the combination of Impella and Protek Duo, which is a dual-lumen cannula inserted via the right internal jugular vein, with its proximal inflow lumen positioned in the right atrium and distal lumen positioned in the main pulmonary artery. These lumens are connected with the paracorporeal TandemHeart pump allowing flows up to 5 L/min. The alternative percutaneous option for right ventricular support is the Impella RP (Abiomed), which has to be placed in the femoral vein, preventing ambulation. The axillary and internal jugular vein positions for devices are probably less prone to infection compared to the femoral area. The combination of an Impella inserted via the axillary artery with the Protek Duo is a viable option, allowing ambulation while providing biventricular support.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
11:27Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy
Published on: February 7, 2015
Related Concept Videos
Anatomy of the Circulatory System
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps: