Related Experiment Video
Updated: Jan 30, 2026

Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder
Published on: March 4, 2018
Quantitative Evaluation of Gait Disturbance on an Instrumented Timed Up-and-go Test
Shigeki Yamada1,2, Yukihiko Aoyagi3, Kazuo Yamamoto2
11Normal Pressure Hydrocephalus Center, Rakuwakai Otowa Hospital, Rakuwakai Healthcare System, Kyoto, Japan.
Abstract:
Although the 3-m timed up-and-go test (TUG) is reliable for evaluating mobility, TUG time is insufficient to evaluate mild gait disturbance; we, therefore aimed to investigate other measurements with instrumented TUG (iTUG) using a free smartphone application. Our inclusion criterion in this study is only that participants can walk without any assistance. This study included three heterogeneous groups; patients who underwent a tap test or shunt surgery, 29 inpatients hospitalized for other reasons, and 87 day-care users. After the tap test, 28 were diagnosed with tap-positive idiopathic normal-pressure hydrocephalus (iNPH) and 8 were diagnosed with tap-negative. Additionally, 18 patients were assessed iTUG before and after shunt surgery. During iTUG, time and 3-dimensional (3D) acceleration were automatically recorded every 0.01 s. A volume of the 95% confidence ellipsoid (95%CE) of all plots for 3D acceleration was calculated. Additionally, an iTUG score was defined as (95%CE volume) 0.8 / 1.9 - 1.9 × (time) + 60. The measurement reliability was evaluated using intraclass correlations and Bland-Altman plots. The participants with mild gait disturbance who accomplished within 13.5 s on the iTUG time had the 95%CE volumes for 3D acceleration of ≥70 m3/s6 and iTUG scores of ≥50. The mean iTUG time was shortened and the mean 95%CE volumes and iTUG scores were increased after the tap test among 28 patients with tap-positive iNPH and after shunt surgery among 18 patients with definite iNPH. Conversely, the mean iTUG score among 8 patients with tap-negative was decreased after the tap test. The intraclass correlations for the time, 95%CE volume and iTUG score were 0.97, 0.80 and 0.90, respectively. Not only the iTUG time but also the 95%CE volume was important for evaluating mobility. Therefore, the novel iTUG score consisting both is useful for the quantitative assessment of mobility.
Related Concept Videos
Ecological Disturbance
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Uncertainty in Measurement: Reading Instruments
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers

