Related Experiment Video
Updated: Jan 30, 2026

Layer-by-layer Collagen Deposition in Microfluidic Devices for Microtissue Stabilization
Published on: September 29, 2015
Needle-free pneumatic injection device; histologic assessment using a rat model and parameter comparison in
Seung Hyun Chun1, Bo Young Kim1, Sheila Natari2
1Department of Dermatology, Korea University Ansan Hospital, 123 Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, Korea.
Background:
Needle-free pneumatic injections have been recently introduced to the field of dermatology to inject such substances as hyaluronic acid. However, data on the influence of various pneumatic injection parameters on collagen synthesis are lacking.
Objective:
Compare the effect of diameter, pressure, and volume of a pneumatic injection jet on collagen synthesis and fluid dispersion pattern using a rat model. Investigate if the total work force of the injection jet is useful in predicting the degree of collagen synthesis.
Materials And Methods:
We injected fluid with 1 mg/ml of hyaluronic concentration to adult rats. Different injection pressures and volumes were tested using devices with nozzles of different diameters. Collagen synthesis areas were then measured, and statistical analyses were performed.
Results:
The area of collagen fibers increased for up to two months. The injection pressure and volume did not correlate with the degree of collagen synthesis. The nozzle diameter showed a significant after two and four weeks of injection. The total work force correlated with collagen synthesis 2, 4, and 8 weeks post-injection. (P = 0.043, 0.027, and 0.000, respectively).
Conclusion:
Collagen formation is more prominent 2 months post-hyaluronic acid injection than after 1 month when using a needle-free pneumatic injection device. The total work force, which is affected by both the nozzle diameter and injection pressure, can be helpful in predicting the degree of collagen synthesis. Lasers Surg. Med. 51:278-285, 2019. © 2019 Wiley Periodicals, Inc.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.