Recommendations for reporting ion mobility Mass Spectrometry measurements
Valérie Gabelica1, Alexandre A Shvartsburg2, Carlos Afonso3
1University of Bordeaux, INSERM and CNRS, ARNA Laboratory, IECB site, 2 rue Robert Escarpit, 33600, Pessac, France.
This guide clarifies ion mobility mass spectrometry (IM-MS) experiments, detailing measurements, methods, and reporting for mobility and collision cross section (CCS) values. It emphasizes accurate reporting to enhance data reusability and calls for community standards.
Area of Science:
- Analytical Chemistry
- Physical Chemistry
- Spectrometry
Background:
- Ion mobility mass spectrometry (IM-MS) is a powerful technique for analyzing ions in the gas phase.
- Standardized reporting of IM-MS data is crucial for reproducibility and data sharing.
- Existing methods and reporting practices can lead to confusion and method-dependent results.
Purpose of the Study:
- To provide a comprehensive guide to ion mobility mass spectrometry experiments, covering linear and nonlinear methods.
- To clarify fundamental concepts and reporting recommendations for mobility and collision cross section (CCS) values.
- To promote confident reuse of IM-MS data through standardized reporting.
Main Methods:
- Detailed explanation of what is measured in IM-MS experiments.
- Description of how linear and nonlinear IM-MS measurements are performed.
- Guidance on reporting mobility (K0) and CCS values, including uncertainties.
Main Results:
- Mobility values (K0) are intrinsically dependent on ion structure, bath gas, temperature, and E/N.
- Collision cross section (CCS) values are derived from mobility, not direct surface measurements.
- Calibrated methods can be empirical and method-dependent if not aligned with primary methods.
Conclusions:
- Accurate reporting of IM-MS data is essential for reliable interpretation and reuse.
- There is an urgent need for community-wide efforts to establish primary standards and reference materials for ion mobility.
- Implementing the recommended reporting practices will improve the quality and comparability of IM-MS results.
More Related Videos
16:40T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
Published on: July 31, 2010
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Mass Spectrometry: Overview
Tandem Mass Spectrometry
Mass Spectrometry of Amines
Mass Spectrometry: Isotope Effect
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Alkene Fragmentation