Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Advancements and Challenges in Surgical Treatments for Postamputation Pain
Published on: March 8, 2024
Effectiveness of part-time vs full-time wear protocols of Twin-block appliance on dental and skeletal changes: A
Jeet Parekh1, Kate Counihan1, Padhraig S Fleming1
1Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom.
Introduction:
The aim of this 2-arm parallel study was to compare the dentoalveolar and skeletal changes achieved with Twin-block appliance therapy prescribed on either a part- or full-time basis for 12 months.
Methods:
Sixty-two 10- to 14-year-old patients were randomly allocated to either full-time (FT, 22 hours daily) or part-time (PT, 12 hours daily) wear of a modified Twin-block appliance. Participants were recruited from the Institute of Dentistry, Barts and the London School of Medicine and Dentistry, London, United Kingdom, and recalled at 6- to 8-week intervals. Electronic randomization was undertaken, with group allocation concealed using opaque, sealed envelopes. The outcome assessor was blinded; however, it was not feasible to blind either operator or patients. Study models and cephalograms were taken at baseline and after 12 months of treatment.
Results:
Data from 55 of the 62 participants were analyzed. Overjets were reduced by 7 mm (SD, 2.92) in the PT group and 6.5 mm (SD, 2.62) in the FT group, with no statistical difference between the groups (P = 0.587; 95% CI, -1.01, 1.78). Similarly, no clinical or statistical differences were noted for skeletal changes: ANB angle (PT, -1.51°; FT, -1.25°; P = 0.828; 95% CI, -0.68, 0.849), pogonion-sella vertical (PT, 3.25 mm; FT, 3.35 mm) or A-sella vertical (PT, 1.28 mm; FT, 1.06 mm). Mean wear durations were 8.78 hours a day in the PT group and 12.38 hours in the FT group.
Conclusions:
There was no difference in either dental or skeletal changes achieved with PT or FT wear of a Twin-block appliance over 12 months. Less onerous PT wear regimens may therefore be a viable alternative to FT wear of removable functional appliances.
Registration:
NCT02190630.
Protocol:
The protocol was not published before trial commencement.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Mean free path and Mean free time

