Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
Development of competitive lateral flow immunoassay coupled with silver enhancement for simple and sensitive salivary
Amara Apilux1, Sirirat Rengpipat2, Wilasinee Suwanjang3
1Department of Clinical Chemistry, Faculty of Medical Technology, Mahidol University, 999 Phutthamonthon 4 Road, Salaya, Nakhon Pathom 73170, Thailand.
Abstract:
Cortisol is known as a stress biomarker. The measurement of cortisol levels is an early warning indicator for health conditions and diagnosis of stress-related diseases. Herein, a lateral flow immunoassay using a gold nanoparticle label with a silver enhancement system was developed for the simple, sensitive and rapid detection of cortisol. The developed assay was based on a competitive platform of which cortisol-BSA conjugate was immobilized at the test zone to compete with an analyte. The quantitative analysis was performed using gold nanoparticles (AuNPs) as signal labeling. Sequentially, the silver enhancement solution was applied in order to enhance the sensitivity of the assay with the results easily seen by the naked eye. Using this system, the limit of detection (LOD) was found to be 0.5 ng/mL with a 3.6 fold more sensitive detection than without the enhancement system (LOD = 1.8 ng/mL). The salivary cortisol analysis was in the range of 0.5-150 ng/mL (R2 = 0.9984), which is in the clinical acceptable range. For the semi-quantitative analysis, the intensity color of the results was analyzed using an image processing program. The proposed method was successfully applied to detect cortisol in saliva. In addition, the results from our method also complied with the ones of those obtained by using the commercial enzyme-linked immunosorbent assay (ELISA). This developed assay offers great promise for a non-invasive screening test of salivary cortisol.
More Related Videos
09:08Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
08:25Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
Related Concept Videos
Competition
Salivary Glands and Saliva
Lateralization
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
G-protein Coupled Receptors