Field-compatible protocol for detecting tetracyclines with bioluminescent bioreporters without pipetting steps
Johanna Muurinen1, Avinash Pasupulate1, Juha Lappalainen2
1Department of Microbiology, University of Helsinki, Helsinki, Finland.
Abstract:
Whole-cell bioreporters are living organisms and thus using them for detecting environmental contaminants would reflect biological effects of these pollutants. However, bioreporters are not widely used in field studies. Many of the bioreporter field protocols are suitable for liquid samples or include pipetting steps, which is a demanding task outside the laboratory. We present a bioreporter protocol without pipetting or sample type requirements. The protocol utilizes polyester swabs, commonly used in cleanroom technology. As an example contaminant, we used tetracycline and generated test samples with known concentrations up to the maximum tetracycline residue limit of milk set by the European Union (EU) regulation. The matrices of the test samples were Milli-Q water, milk and soil. The swabs were first dipped in the bioreporter cell cultures and then to test samples and luminescence was measured after incubation. The standard deviation of measurements from ten replicate swabs was in the same range as commonly in pipetting protocols (4-19%). The test samples with lowest tetracycline concentration (5 ng mL-1 ) were distinguished from the control samples (0 ng mL-1 tetracycline). Our results show that swabs can be used together with luminescent whole cell bioreporters, making it possible to conduct the measurements in field conditions.
Related Concept Videos
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Steps in Outbreak Investigation
Steps in the Modeling Process
Attention is the first necessary component for observational learning. It involves focusing on what the model is doing and saying. For example, if you decide to take a drawing class to enhance your skills, you need to pay close attention to the instructor's words and hand movements. The characteristics of the model significantly...
Steps for Free-Body Diagram
To find the acceleration of the system, it is first necessary to calculate the net force on the system. In order to accomplish this, a free-body diagram can be created to...
Multi-Step Reactions
Field Effect Transistor