Transvenous Extraction and Removal of Pacing Leads Placed after Cardiac Transplantation
Caleb Norton1, Benjamin Holmes2, Asad Al Aboud2
1Department of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA.
Abstract:
There is an increasing prevalence of cardiac implantable electronic devices (CIEDs) due to expanding adoption and availability of these evidence-based therapies. With the increased prevalence of these life-saving devices, there has also been an increased demand for lead removal and lead extraction. Understanding the specific subgroups of patients at high risk for complications during and after lead extraction has become imperative to properly manage endovascular CIED leads. There have been multiple published studies describing clinical variables that predict adverse outcomes in CIED system extractions; however, the risk of complications in leads placed after cardiac transplantation has not specifically been addressed to date. We present four cases of transvenous extraction and removal of pacing leads placed after cardiac transplantation. There were no major complications related to extraction in these four cases; however, three of the four patients died within one year after the procedure. While the etiology of death in these cases seemed to be unrelated to the extraction procedure, the indications for extraction (infection in the setting of immunosuppression and calcineurin-associated ESRD and poor sensing/capture possibly secondary to chronic rejection and/or frequent right heart biopsies) likely contributed at least indirectly to the subsequent death.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
09:25An Immunological Model for Heterotopic Heart and Cardiac Muscle Cell Transplantation in Rats
Published on: May 8, 2020
Related Concept Videos
Phase-lead and Phase-lag Controllers
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...