Continuous Monitoring of Transplant Center Performance: Different Options for Different Goals
Brian Alexandrine1, Emilie Savoye1, Fabienne Pessione1
1Agence de la biomédecine, Direction Prélèvement Greffe Organes-Tissus, Saint Denis la Plaine, France.
Background:
In France, the need for continuous monitoring of transplant center performance has recently become apparent. Cumulative sum (CUSUM) monitoring of transplantation is already been used to monitor transplant outcomes in the United Kingdom and in the United States. Because CUSUM monitoring can be applied by different methods, the objective was to assess and compare the performance of different CUSUM methods for detecting higher than expected (ie, excessive) graft failure rates.
Methods:
Data come from the French transplant registry. Lung and kidney transplants in 2011-2013 constituted the control cohort, and those in 2014-2016 the observed cohort. The performance of CUSUM monitoring, according to center type and predefined control limits, was measured by simulation. The outcome monitored was 3-month graft failure.
Results:
In a low-volume center with a low failure rate, 3 different types of control limits produced successful detection rates of excessive graft failures of 15%, 62%, and 73% and false alarm rates of 5%, 40%, and 52%, with 3, 1, and 1 excess failures necessary before a signal occurred. In a high-volume center with a high failure rate, successful detection rates were 83%, 93%, and 100% and false alarm rates were 5%, 16%, and 69%, with 6, 13, and 17 excess failures necessary before a signal occurred.
Conclusions:
CUSUM performances vary greatly depending on the type of control limit used. A new control limit set to maximize specificity and sensitivity of detection is an appropriate alternative to those commonly used. Continued attention is necessary for centers with characteristics making it difficult to obtain adequate sensitivity or sufficiently prompt response.
More Related Videos
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
07:58Orthotopic Kidney Auto-Transplantation in a Porcine Model Using 24 Hours Organ Preservation And Continuous Telemetry
Published on: August 21, 2020
Related Concept Videos
Psychosis: Goals of Pharmacotherapy
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Instantaneous Center of Zero Velocity
To analyze this, consider two points on the wheel: point A and point B. The absolute velocity of point B can be expressed as the vector sum of the absolute velocity of point A and the relative velocity of point B with respect to point A. To simplify this analysis,...