Related Experiment Video
Updated: Jan 29, 2026

Isolated Hepatic Perfusion as a Treatment for Liver Metastases of Uveal Melanoma
Published on: January 25, 2015
The Lens Opacities Classification System III Grading in Irradiated Uveal Melanomas to Characterize Proton
Thibaud Mathis1, Laurence Rosier2, Fatima Meniai3
1Department of Ophthalmology, Croix-Rousse University Hospital, Hospices Civils de Lyon, Lyon, France; UMR-CNRS 5510 Matéis, Villeurbane, France.
Purpose:
To evaluate the use of the Lens Opacities Classification System III grading (LOCS III) for the characterization of radiation-induced cataract, and to correlate the proton beam projection onto the lens with cataract location and grade as defined by the LOCS III.
Design:
Prospective, interventional case series.
Methods:
Fifty-two consecutive patients with cataract following proton therapy were included. All cataracts were graded using LOCS III. Relationships between proton beam and cataract subtypes, as well as between dose, proportion of lens irradiated, and extent of cataracts, were assessed.
Results:
Tumor diameter, volume, stage, and equatorial tumor location were associated with extent of posterior subcapsular cataracts (PSC) that were diagnosed at a median (interquartile range) 36 months (22;83) after treatment. In multivariate analysis, the tumor volume (P < .01) and an equatorial tumor location (P = .01) were risk factors for extensive PSC. Lens irradiation was avoided in 10 patients. In the remaining 42 patients (81%), the extent of PSC significantly correlated with the dose to the lens receiving 10, 26, and 47 Gy (P = .03, P = .03, and P = .04, respectively), the dose to the lens periphery receiving 10 and 26 Gy (P = .02 and P = .02, respectively), and the dose to the ciliary body receiving 10 and 26 Gy (P = .03 and P = .02, respectively). Nuclear color significantly correlated with the dose to the ciliary body receiving 10 Gy (P = .03) and 26 Gy (P = .02). After adjustment of the results on tumor volume and tumor location, the volume of lens receiving 10 Gy (P = .04) and 26 Gy (P = .03) remained significantly associated with the extent of PSC.
Conclusions:
Proton dose correlated with the occurrence of PSC and nuclear color cataracts as defined by LOCS III grading. Better characterization of cataracts with the LOCS III after irradiation may help to further fill gaps in the current understanding of the mechanisms of radiation-induced cataracts.
More Related Videos
Related Concept Videos
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
Types of Aggregate Grading
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
Inflammatory Bowel Disease III: Diagnostic Studies and Management I-Nutritional Therapy
Diagnostic studies
A colonoscopy is the definitive screening test, distinguishing ulcerative colitis from other colon diseases with similar symptoms. During a colonoscopy test, inflamed mucosa with exudate ulcerations can be observed, and biopsies are taken to determine the histologic characteristics of the...
Sieve Analysis and Grading Curves
Force Classification
Contact and non-contact forces are two of the most widely used categories of forces. As the name suggests, contact forces require physical contact between two objects to act upon each other. Examples of contact forces include frictional,...
Classification of Neurotransmitters

