Related Experiment Video
Updated: Jan 29, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Inappropriate Defibrillator Shocks due to Mechanical Inference from an Investigational Device
Ying Chi Yang1, Thein Tun Aung1, Abdul Wase2
1University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
Abstract:
Cardiac contractility modulation (CCM) is an investigational device-based therapy to enhance ventricular contractility in systolic heart failure patients who are not candidates for cardiac resynchronization therapy (CRT) owing to the absence of wide QRS complexes or who have failed to respond on CRT. The principal mechanism is based on the stimulation of cardiac muscles by nonexcitatory electrical signals to augment the influx of calcium ions into the cardiomyocytes. The majority of patients receiving CCM therapy have concurrent implantable cardioverter defibrillators, and the manufacturer declares both devices can be used in parallel without any interactions. Nevertheless, proper lead positioning of both devices are crucial, and it is mandatory to check device-device interactions during each and every cardiac electronic implantable device-related procedure to prevent adverse outcomes.
More Related Videos
Related Concept Videos
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Theory of Attribution I: Correspondent Inference Theory
Statistical Inference Techniques in Hypothesis Testing: Parametric Versus Nonparametric Data
Parametric statistics, as the name suggests, assumes that data follow a specific distribution, often a normal distribution. This assumption enables robust hypothesis testing and estimation. Parametric methods, like the Student's t-test or Goodness-of-fit test, are frequently employed in biostatistics due to their robustness. For instance,...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Mechanical Protein Functions