A stochastic frontier analysis for enhanced treatment quality of high-dose-rate brachytherapy plans
Paul Edimo1,2, Angelika Kroshko1,2, Luc Beaulieu1,2
1Département de Radio-Oncologie et CR CHU de Québec, Université Laval, 11 Côte du Palais, Québec (QC), G1R 2J6, Canada.
Abstract:
The purpose of the present study is to develop patient specific unbiased quality control (QC) models for high dose rate (HDR) brachytherapy plans. The proposed models are based on the stochastic frontier analysis formalism, a method of economic modeling. They act as a QC tool by predicting before the treatment planning process starts, the dosimetric coverage achievable for a HDR brachytherapy prostate plan. The geometric parameters considered in developing the models were: patient clinical target volume (CTV), organs at risk (OAR) volume, the bidirectional Hausdorff distance between CTV and OARs, and a fourth parameter measuring the catheters degree of non-parallelism within the target volume. Dosimetry parameters of interest are V100 for the CTV, V75 (bladder, rectum) and D10 (urethra). Results show that the built models can provide valuable information on the personalization of the optimization process based on the patient geometric parameters. The impact on the quality plan due to the planner's experience variability and judgment can be reduced by using those models, since the planner will attempt to achieve dosimetric parameters predicted by the models. Furthermore, the models provide information on the better trade-off between the target volume coverage and OARs sparing that can be achieved, regardless of the planner's experience; the latter being achieved by moving each plan at least around their respective frontier for V100, V75 and D10. The shortfall of the dosimetric parameters values computed by the treatment planning system (TPS) from those predicted by the models for a proportion of plans in the dataset reveals that optimized plans from a TPS, even clinically acceptable, are not necessarily the best that could be achieved. These represent 83% of plans in the training set for the target volume coverage (V100), ∼50% for the bladder (V75) and ∼72% for the urethra (D10).
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Dose Size and Dosing Frequency: Determination Methods
Planning Nursing Care I
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...