Related Experiment Video
Updated: Jan 29, 2026

In vivo Imaging of Biological Tissues with Combined Two-Photon Fluorescence and Stimulated Raman Scattering Microscopy
Published on: December 20, 2021
Dual-wavelength digital holographic phase and fluorescence microscopy combining with Raman spectroscopy for
Abstract:
Dual-wavelength digital holographic phase and fluorescence microscopy (DW-DHPFM), combining with Raman spectroscopy, is designed to achieve the detection and analysis of biomolecules with a new dual-channel encoding method. This employs the Raman reporter molecules assembled micro-quartz pieces (MQPs) as microcarriers of suspension array (SA). The dual-wavelength digital holographic phase microscopy (DW-DHPM) and Raman spectroscopy are served as the decoding platforms, and the fluorescence microscopy is used to quantify target analytes. Considering the independence between encoding and label signal, the above two encoding channels could effectively avoid the crosstalk in immunoassay process, and the combination of two encoding methods expand the encoding capacity with a considerable magnitude. Accurate and stable decoding abilities are verified by multiplexed immunoassay experiment and the quantitative analysis of targets with high-sensitivity is confirmed by concentration gradient experiments.
More Related Videos
07:38Multimodal Quantitative Phase Imaging with Digital Holographic Microscopy Accurately Assesses Intestinal Inflammation and Epithelial Wound Healing
Published on: September 13, 2016
07:27Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy DHM
Published on: November 1, 2017
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The de Broglie Wavelength
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Atomic Fluorescence Spectroscopy
Encoding
Automatic processing involves the encoding of details like time, space, frequency, and the meaning of words, usually done without conscious...