Automated 3-Dimensional Magnetic Resonance Imaging Allows for Accurate Evaluation of Glenoid Bone Loss Compared With
Drew A Lansdown1, Gregory L Cvetanovich2, Nikhil N Verma3
1Department of Orthopedic Surgery, University of California, San Francisco, San Francisco, California, U.S.A..
Purpose:
To evaluate clinical measurements of glenoid bone loss based on 3-dimensional (3D) computed tomography (CT) and automatically segmented 3D reconstructions from Dixon fat-water magnetic resonance (MR) imaging.
Methods:
Available CT and MR studies from 16 patients with recurrent anterior shoulder instability were retrospectively reviewed. Three-dimensional reconstructions were formed independently by 2 observers using freely available software and a simple threshold-based segmentation (3D Slicer, version 4.8.0; http://www.slicer.org). Bone loss was estimated with the perfect-circle method. Intra-user and interuser reproducibility was determined with intraclass correlation coefficients. Bland-Altman plots were used to evaluate the similarity between imaging modalities.
Results:
Differences between MR and CT estimates of bone loss ranged from 0% to 6%. The individual intraclass correlation coefficients showed good to excellent reliability, with intraobserver comparisons between MR- and CT-based bone loss estimates ranging from 0.94 to 0.99. Bland-Altman plots showed 95% confidence intervals from -5% to 6% for differences between MR and CT estimates, with 88% of all measurements (42 of 48) showing a less than 2% difference between MR and CT estimates.
Conclusions:
The described methodology for obtaining an MR-based 3D reconstruction of the glenoid can evaluate glenoid bone loss similarly to the performance of a 3D CT reconstruction. The results may allow surgeons to simplify the preoperative imaging protocol for patients with recurrent shoulder stabilization and limit the number of shoulder CT scans.
Level Of Evidence:
Level III, retrospective therapeutic trial.
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...