Related Experiment Video
Updated: Jan 29, 2026

Recording Temperature-induced Neuronal Activity through Monitoring Calcium Changes in the Olfactory Bulb of Xenopus laevis
Published on: June 3, 2016
Strong, weak and neuron type dependent lateral inhibition in the olfactory bulb
Ronit Shmuel1, Lavi Secundo2, Rafi Haddad3
1Gonda Multidisciplinary Brain Research Center, Bar-Ilan University, Ramat-Gan, Israel.
Abstract:
In many sensory systems, different sensory features are transmitted in parallel by several different types of output neurons. In the mouse olfactory bulb, there are only two output neuron types, the mitral and tufted cells (M/T), which receive similar odor inputs, but they are believed to transmit different odor characteristics. How these two neuron types deliver different odor information is unclear. Here, by combining electrophysiology and optogenetics, it is shown that distinct inhibitory networks modulate M/T cell responses differently. Overall strong lateral inhibition was scarce, with most neurons receiving lateral inhibition from a handful of unorganized surrounding glomeruli (~5% on average). However, there was a considerable variability between different neuron types in the strength and frequency of lateral inhibition. Strong lateral inhibition was mostly found in neurons locked to the first half of the respiration cycle. In contrast, weak inhibition arriving from many surrounding glomeruli was relatively more common in neurons locked to the late phase of the respiration cycle. Proximal neurons could receive different levels of inhibition. These results suggest that there is considerable diversity in the way M/T cells process odors so that even neurons that receive the same odor input transmit different odor information to the cortex.
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Weak Acid with a Strong Base
Weak Base Solutions
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Weak Acid Solutions

