Related Experiment Video
Updated: Jan 29, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Iris suture fixation of out-of-the-bag dislocated three-piece intraocular lenses
Laura Armonaite1, Stefan Löfgren1, Anders Behndig2
1Department of Clinical Neuroscience, Division of Ophthalmology and Vision, St. Erik Eye Hospital, Karolinska Institutet, Stockholm, Sweden.
Purpose:
To evaluate the efficacy and safety of iris suture fixation of out-of-the-bag dislocated three-piece intraocular lenses (IOL).
Methods:
In a retrospective interventional consecutive case series, a chart review was performed in two groups of patients: fourteen patients with a dislocated out-of-the-bag three-piece IOL that underwent IOL fixation to the iris using the Siepser sliding knot technique (Iris group) and 18 patients with in-the-bag dislocation that underwent IOL exchange with a new scleral-sutured IOL (Exchange group). The Iris and Exchange groups were compared regarding surgical safety and efficacy. The median follow-up time was 13.5 months [interquartile range (IQR), 10-20] in the Iris group and 12.5 (IQR, 10-14) in the Exchange group.
Results:
The best corrected visual acuity (BCVA) improved significantly in both groups (p = 0.005 and 0.00006, respectively). No difference in final BCVA was seen between the groups. Significantly less surgically induced astigmatism (p = 0.03) and a lower number of postoperative visits (p = 0.0006) was noted in the Iris group. Considering the type of surgery, there were few complications in the present material.
Conclusion:
In the study, suturing dislocated three-piece IOLs to the iris appeared to be an acceptable surgical management with less surgically induced corneal astigmatism and fewer postoperative visits than IOL exchange. A larger study with a longer follow-up time would be desirable to confirm the results.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
The Roles of Bacteria and Fungi in Plant Nutrition
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...