The Impulse Response of Negatively Focused Spherical Ultrasound Detectors and Its Effect on Tomographic Optoacoustic Reconstruction
Related Experiment Video
Updated: Jan 29, 2026

Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
Abstract:
In optoacoustic tomography, negatively focused detectors have been shown to improve the tangential image resolution without sacrificing sensitivity. Since no exact inversion formulas exist for optoacoustic image reconstruction with negatively focused detectors, image reconstruction in such cases is based on using the virtual-detector approximation, in which it is assumed that the response of the negatively focused detector is identical, up to a constant time delay, to that of a point-like detector positioned in the detector's center of curvature. In this paper, we analyze the response of negatively focused spherical ultrasound detectors in three dimensions and demonstrate how their properties affect the optoacoustic reconstruction. Our analysis sheds new light on commonly reported experimental reconstruction artifacts in optoacoustic systems that employ negatively focused detectors. Based on our analysis, we introduce a simple correction to the virtual-detector approximation that significantly enhances image contrast and reduces artifacts.
More Related Videos
07:34Delivery of Antibodies into the Brain Using Focused Scanning Ultrasound
Published on: July 18, 2020
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Impulse Response
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is the impulse...
Spherical Coordinates
Impulse
Additionally, it can be shown that the...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gravity between Spherical Bodies
This assumption can be proved easily by showing that the expression for gravitational potential energy between a hollow sphere of mass (M) and a point mass (m) is the same as it would be for a pair of extended...
Spherical and Cylindrical Capacitor
Conventionally, considering the symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...