Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoring
Gil Gelbert1, Ron Moisseev1, Yoav Hazan1
1Andrew and Erna Viterbi Faculty of Electrical & Computer Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
Abstract:
Cuffless blood pressure monitoring is essential for continuous cardiovascular assessment. Current wearable approaches rely on pulse-echo ultrasound patches that track pulsating arterial diameters. However, multi-element designs and precise alignment complicate their applicability as a fully wearable solution. We overcome these challenges by using a highly miniaturized silicon-photonics acoustic detector and optoacoustic excitation to generate ultrasound waves inside the artery. The superior contrast in these optoacoustic signals and the detector's semi-isotropic sensitivity enable robust artery diameter monitoring with a single detection element, achieving high tolerance to translation and rotation. The detector's high sensitivity, achieved despite its small size, enables measuring optoacoustic signals from the radial artery with a high contrast at 100 Hz, capturing the features of the blood pressure waveform. Here, we show that the device's agreement with a reference cuff-based blood pressure monitor highlights the potential of silicon-photonics optoacoustic sensing as a practical solution for continuous, cuffless monitoring in daily life.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:32A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...