Development of geometrically ideal dose distribution as a reference for treatment planning in VMAT using filtered
Kentaro Miki1, Kazunari Hioki2, Takeo Nakashima2
1Department of Radiation Oncology, Hiroshima University Hospital, Japan.
Purpose:
To determine optimal dose distribution in the treatment planning of volumetric modulated arc therapy (VMAT), a virtually ideal dose distribution was developed as a reference by applying filtered back-projection method.
Methods:
Delineated structures in patient CT scans were identified using a treatment planning system. The projection of the planning target volume (PTV) was calculated along the X-ray direction for each angle of rotation. Each projection was Fourier transformed to the frequency space; a Shepp-Logan filter was applied, then an inverse Fourier transformation was performed. As the dose irradiation cannot assume a negative value, the filtered projections were shifted using the minimum value inside of the PTV. All values outside of the PTV were set to zero. The corrected filtered projections were then multiplied by the tissue-maximum ratio according to each voxel depth from the surface of the body to simulate X-ray attenuation. Finally, the distributions of multiple rotational angles were convolved to simulate the dose distribution of the VMAT.
Results:
Ideal dose distributions were generated with sufficient uniformity inside of the PTV. Dose spreading except for the PTV due to external irradiation was reproduced in the case of a brain tumor. A reference dose distribution including OAR sparing was produced. The efficacy of this process as a target for optimum planning was confirmed.
Conclusion:
Using applied filtered back-projection, the ideal dose distribution, which excluded some device-oriented restrictions, was generated. This application will provide support for the determination of VMAT planning quality by providing reference dose distributions.
Related Concept Videos
Geometric Mean
In cases of multiplicative data, the geometric mean is used for statistical analysis. First, the product of all the elements is taken. Then, if there are n elements in the...
Ideal Solutions
Dose Size and Dosing Frequency: Determination Methods
Geometric Sequences
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles