Related Experiment Video
Updated: Jan 29, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Detector for monitoring potential bleeding during electron intraoperative radiotherapy
Enrique Sanchis1, Silvia Casans2, Giuseppe Felici3
1Department of Electronic Engineering, University of Valencia, E-46100, Spain; IRIMED, Unidad Mixta de Investigacion en Radiofisica e Instrumentacion Nuclear en Medicina IIS Hospital La Fe - Universitat de Valencia, Spain.
Purpose:
The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected.
Methods:
An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0° and 45° tilted, both with respect to the horizontal surface, in order to mimic the worst clinical scenario according to the irradiation gantry and applicator bevel angle. The behavior of the detector under irradiation was analyzed and the impact of the stray radiation on the detector was also evaluated.
Results:
The detector was able to distinguish the presence of liquid at a minimum height of 0.5 cm. A linear behavior was obtained for both setups. We have also verified that the LIAC HWL radiation does not affect the measurements nor does the detector interfere with the stray radiation. The bleeding detector is a quasi-digital capacitive sensor with low-cost, high linearity, and easy to install.
Conclusions:
With this detector it is possible to perform a continuous monitoring of the liquid measurements even during the irradiation phase. Thus, it can operate not only as a pre-treatment detector but also as a continuous one.
Related Concept Videos
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Cell Potential and Free Energy
Thermodynamics is the branch of physics dealing with the relationship between heat and other forms of energy. In an electrochemical cell, chemical energy is converted into electrical energy.
Thus, a link can be predicted between cell potential, free energy change, and the equilibrium constant for the reaction. Cell potential can also be measured as the oxidant or the reducing strength, and similar acid-base strength measures are reflected in equilibrium...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Standard Electrode Potentials