Related Experiment Video
Updated: Jan 29, 2026

Breast Milk Enhances Growth of Enteroids: An Ex Vivo Model of Cell Proliferation
Published on: February 15, 2018
Detection of Milk Ejection Using Bioimpedance Spectroscopy in Lactating Women during Milk Expression Using an
Hazel Gardner1, Ching Tat Lai2, Leigh Ward3
1School of Molecular Sciences, Faculty of Science, University of Western Australia, Perth, Australia. Hazel.Gardner@uwa.edu.au.
Abstract:
Milk ejection is essential for effective milk removal during breastfeeding and pumping, and for continued milk synthesis. Many women are unable to accurately sense milk ejection to determine whether their infant is receiving milk or, when pumping, to switch the pump to a more effective expression pattern. To determine if changes in bioimpedance parameters are associated with milk ejection in the lactating breast during pumping. 30 lactating women participated in 2 pumping sessions within 2 weeks of each other. During pumping the breasts were monitored with bioimpedance spectroscopy (on either the pumped or the non- pumped breast), and milk flow rate and volume were measured simultaneously. All mothers completed 24-h milk productions. Linear mixed effects models were used to determine associations between milk flow rate and bioimpedance changes. Changes in bioimpedance parameters were greater at the first milk ejection when measured on the pumped breast (median (IQR): R zero: -7 (-17, -4,) % (n = 30); R infinity: -8 (-20, -2) % (n = 29); membrane capacitance: -24 (-59, -7) % (n = 27). Changes in bioimpedance detected in the non-pumped breast were lower at the first milk ejection, R zero: -3 (-8, -2) % (n = 25); R infinity: -5 (-8, -2) % (n = 23); membrane capacitance: -9 (-17, 15) % (n = 24). Smaller less consistent decreases in the bioimpedance characteristics were detected at the second milk ejection in both breasts. Bioimpedance parameters showed a consistent decrease associated with the first milk ejection when electrodes were placed on the pumped breast. Smaller decreases were observed when the non-pumped breast was monitored for the first and second milk ejection. There was wide variation in the magnitude of changes observed, and hence further development of the methodology is needed to ensure reliability.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Finding Electric Potential From Electric Field

