Related Experiment Video
Updated: Jan 29, 2026

Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
Kinematic Analysis of the Distal Radioulnar Joint in Asymptomatic Wrists Using 4-Dimensional Computed
Delaram Shakoor, Nima Hafezi-Nejad1, Arya Haj-Mirzaian
1Department of Internal Medicine, University of Maryland.
Purpose:
The aim of this study was to determine the normal measurement values and interobserver performance of the distal radioulnar joint during wrist pronation-supination using 4-dimensional computed tomography (CT).
Methods:
Four-dimensional CT examinations were performed on the asymptomatic contralateral wrists of 10 patients with unilateral chronic wrist pain. Measurements were conducted using the modified radioulnar (mRU) line and epicenter (Epi) methods. Volar subluxation of the ulnar head was demonstrated with negative values. Wilcoxon rank sum test was used to determine the measurement changes. Interobserver agreements were assessed using interclass correlation coefficients.
Results:
In pronation, mRU line measurements (median, 0.09; interquartile range, 0-0.15) were significantly larger than in supination (median, -0.1; interquartile range, -0.18 to 0; P = 0.008).The Epi measurements were not significantly different in pronation (median, 0.03; interquartile range, 0.01-0.07) and supination (median, 0.06; interquartile range, 0.01-0.1; P = 0.799). There was an excellent inter-observer agreement between the two readers using mRU and Epi methods in pronation (0.982, 0.898), midpoint (0.994, 0.827) and supination (0.989, 0.972) positions, respectively.
Conclusions:
Using 4-dimensional CT examination, distal radioulnar joint kinematics in asymptomatic wrists demonstrate excellent interobserver agreements with increased volar ulnar subluxation with supination as detected using mRU, but not the Epi method.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Imaging Studies III: Computed Tomography

