Related Experiment Video
Updated: Jan 29, 2026

Isolated Hepatic Perfusion as a Treatment for Liver Metastases of Uveal Melanoma
Published on: January 25, 2015
Corneal Substructure Dosimetry Predicts Corneal Toxicity in Patients With Uveal Melanoma Treated With Proton Beam
Howard J Lee1, Andrew Stacey2, Todd R Klesert3
1Duke University School of Medicine, Durham, North Carolina.
Purpose:
This study examines the relationship between dose to corneal substructures and incidence of corneal toxicity within 6 months of proton beam therapy (PBT) for uveal melanoma. We aim to develop clinically meaningful dose constraints that can be used to mitigate corneal toxicity.
Methods And Materials:
Ninety-two patients were treated with PBT between 2015 and 2017 and evaluated for grade 2+ (GR2+) intervention-requiring corneal toxicity in our prospectively maintained database. Most patients were treated with 50 Gy (relative biological effectiveness [RBE]) in 5 fractions, and all had complete six-month follow-up. Analyses included Mann-Whitney, χ2, Fisher exact, and receiver operating curve tests to identify risk factors for GR2+ toxicity. Bivariate logistic regression was used to identify independent dose-volume histogram (DVH) predictors of toxicity after adjustment for the most important clinical risk factor.
Results:
The 6-month PBT GR2+ corneal toxicity rate was 10.9%, with half of patients experiencing grade 2 toxicity and half experiencing grade 3 toxicity, with no grade 4 events. Patients with anterior chamber tumors had a higher risk (58.3%) for toxicity than those with posterior tumors (0%) or posterior tumors extending past the equator (25%, P < .0001). On univariate analysis, larger size according to Collaborative Ocular Melanoma Studies was associated with increased toxicity rate (P < .004). DVH analysis revealed that cutoffs of 58% for V25, 32% for V45, 51.8 Gy (RBE) for maximum dose, and 32 Gy (RBE) for mean dose to the cornea separated patients into groups experiencing and not experiencing toxicity with 90% sensitivity and ≥96% specificity. Bivariate logistic regression indicated that corneal V25, V45, and mean dose independently predicted for toxicity after adjusting for tumor location.
Conclusions:
Patients receiving PBT for anterior uveal melanomas experience a high rate of GR2+ corneal toxicity because of increased corneal dose. Anterior location and corneal DVH parameters independently predict toxicity risk. We propose dosimetric constraints to facilitate treatment planning and toxicity mitigation.
More Related Videos
04:00Author Spotlight: Establishing a Practical and Cost-Effective Protocol for Corneal Sensitivity Testing in Clinical Settings
Published on: August 2, 2024
04:48Establishing a Severe Corneal Inflammation Model in Rats Based on Corneal Epithelium Curettage Combined with Corneal Sutures
Published on: November 22, 2024
Related Concept Videos
Treating Helicobacter pylori in Peptic Ulcers: Antimicrobial Therapy
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Predicting Molecular Geometry
Gene Therapy
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.