Gas chromatography system constant database over an extended temperature range for nine open-tubular columns
1Department of Chemistry, Wayne State University, Rm 185 Chemistry, Detroit, MI 48202, USA.
Abstract:
The solvation parameter model is used to characterize the retention properties of poly(octylmethylsiloxane), poly(dimethyldiphenylsiloxane), silphenylene-dimethylsiloxane copolymer, poly(dimethylmethyltrifluoropropylsiloxane), poly(3-cyanopropylphenyldimethylsiloxane), and poly(ethylene glycol) (SPB-Octyl, HP-5, Rxi-17, Rxi-5Sil MS, Rtx-OPP, DB-1701, DB-225, Rtx-440 and HP-INNOWAX) stationary phases over an extended temperature range from 60 °C to close to the maximum column operating temperature. System maps constructed from the system constant database are used to evaluate the influence of temperature on the contribution of intermolecular interactions to differences in selectivity. None of the stationary phases are hydrogen-bond acids. Increasing temperature reduces the contribution from cavity formation/dispersion, dipole-type interactions and hydrogen-bond basicity in a stationary phase specific manner with their preservation to the highest temperature studied for each column. Electron lone pair interactions are generally repulsive at lower temperatures becoming attractive and leading to an increase in retention at higher temperatures.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...