3D printed gel electrophoresis device coupling with ICP-MS for online separation and detection of metalloproteins
Dingyi Wang1, Bin He1, Xueting Yan1
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; College of Resources and Environment, University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
We successfully developed a strategy to combine a customized gel electrophoresis device with ICP-MS for online separation and detection of metalloproteins. The self-designed horizontal column gel electrophoresis device was rapidly and easily fabricated in the laboratory via 3D printing with a low cost. The feasibility of 3D printing to fabricate this device was investigated by offline separation of commercial protein standards. And a better separation efficiency was found when using gel tubes printed with higher printing precision. As a proof-of-concept, the performance of the whole system is demonstrated by online separation and detection of both iodinated protein standards and proteins in rat blood plasma samples. Benefits from 3D printing, customized modification or further optimization can be readily achieved for a better protein separation and detection efficiency.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...