Continuous erythrocyte removal and leukocyte separation from whole blood based on viscoelastic cell focusing and the margination phenomenon
Related Experiment Video
Updated: Jan 29, 2026

Selective Harvesting of Marginating-hepatic Leukocytes
Published on: July 21, 2016
Jeonghun Nam1, Jung Yoon2, Jeeyong Kim2
1Department of Laboratory Medicine, College of Medicine, Korea University, Korea University Guro Hospital, Guro 2-Dong, Guro-Gu, Seoul, 152-703, Republic of Korea; Department of Emergency Medicine, College of Medicine, Korea University, 80, Guro-dong, Guro-gu, Seoul, 152-703, Republic of Korea.
The removal of erythrocytes from whole blood is an essential step during sample preparations intended for biomedical analyses and clinical diagnoses. To address the limitations of present methods, such as centrifugation and chemical lysis, we propose a novel microfluidic device for erythrocyte removal with high-efficiency and leukocyte separation from bulk flows of highly concentrated erythrocytes using a viscoelastic non-Newtonian fluid. The proposed device is designed based on the principle of viscoelasticity-induced particle migration toward the center of the microchannel. In addition, we based the functionality of our device on a bio-inspired phenomenon known as margination according to which erythrocytes migrate to the axial center of blood vessels. Fluorescent particles (10 μm) were added to blood suspensions of various concentrations (hematocrit) of erythrocytes in viscoelastic polymer solutions. Optimal hematocrit and flow rate conditions were determined for erythrocyte removal and for the separation of 10 μm particles. We also demonstrated the capability of our device to separate leukocytes with high efficiency (˜94%) and with a high-enrichment factor (10-fold).
The removal of erythrocytes from whole blood is an essential step during sample preparations intended for biomedical analyses and clinical diagnoses. To address the limitations of present methods, such as centrifugation and chemical lysis, we propose a novel microfluidic device for erythrocyte removal with high-efficiency and leukocyte separation from bulk flows of highly concentrated erythrocytes using a viscoelastic non-Newtonian fluid. The proposed device is designed based on the principle of viscoelasticity-induced particle migration toward the center of the microchannel. In addition, we based the functionality of our device on a bio-inspired phenomenon known as margination according to which erythrocytes migrate to the axial center of blood vessels. Fluorescent particles (10 μm) were added to blood suspensions of various concentrations (hematocrit) of erythrocytes in viscoelastic polymer solutions. Optimal hematocrit and flow rate conditions were determined for erythrocyte removal and for the separation of 10 μm particles. We also demonstrated the capability of our device to separate leukocytes with high efficiency (˜94%) and with a high-enrichment factor (10-fold).
Related Concept Videos
Tip-of-the-Tongue Phenomenon
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Lifecycle of Erythrocytes
The resident phagocytic macrophages deal with these damaged cells by engulfing them and separating their globin and heme groups....
Disorders of Erythrocytes
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...
Margin of Error
Overview Of Cell Separation And Isolation

