1Division of Cardiovascular Imaging, Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC, USA; University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Groningen, the Netherlands.
Background:
The aim of this study was to assess the potential of rest-stress DECT iodine quantification to discriminate between normal, ischemic, and infarcted myocardium.
Methods:
Patients who underwent rest-stress DECT on a 2nd generation dual-source system and cardiac magnetic resonance (CMR) were retrospectively included from a prospective study cohort. CMR was performed to identify ischemic and infarcted myocardium and categorize patients into ischemic, infarcted, and control groups. Controls were analyzed on a per-slice and per-segment basis. Regions of interest (ROIs) were placed in ischemic and infarcted areas based on CMR. Additionally, ROIs were placed in the septal area to assess normal and remote myocardium.
Results:
We included 42 patients: 10 ischemic, 17 infarcted, and 15 controls. Iodine concentrations showed no significant between segments in controls. Iodine concentrations for normal myocardium increased significantly from rest to stress (median 3.7 mg/mL (interquartile range 3.5-3.9) vs. 4.5 mg/mL (4.3-4.9)) (p < 0.001). Iodine concentrations in diseased myocardium were significantly lower than in normal myocardium; 1.3 mg/mL (0.9-1.8) and 0.6 mg/mL (0.4-0.8) at rest and stress in ischemic myocardium, and 0.3 mg/mL (0.3-0.5) and 0.5 mg/mL (0.5-0.7) at rest and stress in infarcted myocardium (p < 0.005 and p < 0.001). At rest only, iodine concentrations were significantly lower in infarcted vs. ischemic myocardium (p < 0.001). The optimal threshold for differentiating diseased from normal myocardium was 2.5 mg/mL and 2.1 mg/mL for rest and stress (AUC 1.00). To discriminate ischemic from infarcted myocardium, the optimal threshold was 1.0 mg/ml (AUC 0.944) at rest.
Conclusion:
DECT iodine concentration from rest-stress imaging can potentially differentiate between normal, ischemic, and infarcted myocardium.
Related Concept Videos
Elastic Strain Energy for Normal Stresses
If...
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
The Resting Membrane Potential
Elastic Strain Energy for Shearing Stresses
What is Energy?
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...