Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Advancing Therapeutic Strategies for Improving Pregnancy Rates by Analyzing Embryo-Endometrium Interactions
Published on: June 21, 2024
Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed
Motaz S Osman1, Hassan M Ziada2, Neamat H Abubakr3
1Department of Oral rehabilitation, Faculty of Dentistry, University of Khartoum, Khartoum, Sudan.
Background:
The outcome of the evaluation of impression techniques accuracy may improve the selection criteria for an ideal technique. The aim was to evaluate the accuracy of the open and closed tray techniques for implant impressions, in a partially edentulous maxilla, replaced with a three-unit fixed partial denture, as well as to assess the effect of implants parallelism on accuracy.
Material And Methods:
This is an experimental in vitro study to evaluate impressions accuracy of a simulated area restored with an implant retained FPD, using the open and closed tray implant impression techniques. The effect of implant position angulation, parallelism, and implant systems (Straumann, SIC Invent, Osstem) was also evaluated. Three custom-made acrylic resin test models were prepared with two parallel and two non-parallel implants, on either side of a maxillary arch. One hundred and ninety-two impressions were made using monophase VPS impression material. Their master casts were obtained and evaluated for the horizontal and vertical discrepancy. The casts were scanned using a model scanner. The distances between the two reference points were measured.
Results:
The Straumann and SIC Invent implants showed no statistically significant differences (Mann-Whitney U test), regarding accuracy for both the open and closed tray impression techniques (P = 0.667 and P = 0.472). There were no significant differences for the parallel and non-parallel implants (P = 0.323 and P = 0.814), respectively, while the Osstem system showed statistically significant differences for both the open and closed tray impression techniques (P = 0.035) and between the parallel and non-parallel implants (P = 0.045). For the vertical discrepancies, significant differences were detected (chi-square test) between the open and closed tray impression techniques (P = 0.037).
Conclusions:
Within the limitations of this study, there were generally no significant differences between open and closed, although better results were obtained for the open tray techniques. On the use of the non-parallel implants, the open tray technique provided a better result than the closed tray technique.
More Related Videos
13:45A Novel Surgical Technique in a Sheep Model for Suburethral Graft Implantation
Published on: June 20, 2025
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
Related Concept Videos
Parallel Resonance
Parallel Processing
Resistors In Parallel
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Parallel-axis Theorem
Capacitors in Series and Parallel
Suppose the capacitors are connected one after the other such that the negative terminal of the first connects to the positive terminal of the...