Published on: September 12, 2018
3D Printing of Photocuring Elastomers with Excellent Mechanical Strength and Resilience
Zhongying Ji1,2, Xiaoqin Zhang1, Changyou Yan1,2
1State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, China.
Abstract:
Three-dimensional (3D) printing elastomers, as a combination of transformative technology and widely used materials, have received great demand in many fields. However, commercial photocuring elastomer inks for 3D printing usually exhibit poor mechanical strength, inferior resilience, and lower elongation at break. In this study, photocuring inks that can be employed for digital light processing 3D printing are developed with acryloyl-modified polyethylene glycol (Acryl@PEG). The resultant photocuring inks exhibit not only high tensile strength of 14.1 MPa and elongation of 245.0%, but also excellent resilience (recover to 90.85% after 30 min under the 200% strain). With the photocuring elastomer inks, a variety of architectures including hollow vases, eggs, finger rings, and porous lattices are built with excellent precision, which all could experience large shape deformations repeatedly without any damage, indicating the excellent elasticity, outstanding shape-recovery property, and mechanical stability. The present photocuring elastomer inks for 3D printing are therefore believed to be promising for soft robots, wearable devices, flexible electronics, and many other applications.
Related Concept Videos
Microsoft Excel: Plotting Mean, SD, and SE
First, calculate the mean, SD, and SE of your data. The mean is obtained using the formula `=AVERAGE(range)`, while SD can be calculated with `=STDEV.P(range)` for a population or `=STDEV.S(range)` for a sample. SE is calculated as `=SD/SQRT(n)`, where `n` is the sample size.
To plot these values, use a bar...
Microsoft Excel: Student's t-Test
To conduct a t-test in Excel, use the T.TEST function or the "Data...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Microsoft Excel: Pearson's Correlation
Microsoft Excel: Regression Analysis
To perform regression...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...