Related Experiment Video
Updated: Jan 28, 2026

AC Electrokinetic Phenomena Generated by Microelectrode Structures
Published on: July 28, 2008
Performance improvement of plasmonic sensors using a combination of AC electrokinetic effects for (bio)target capture
Quentin Avenas1,2, Julien Moreau3, Marion Costella1,4
1Laboratoire Nanotechnologies et Nanosystèmes, LN2, CNRS - Université de Sherbrooke - INSA Lyon, Sherbrooke, Canada.
Abstract:
Analytes concentration techniques are being developed with the appealing expectation to boost the performance of biosensors. One promising method lies in the use of electrokinetic forces. We present hereafter a new design for a microstructured plasmonic sensor which is obtained by conventional microfabrication techniques, and which can easily be adapted on a classical surface plasmon resonance imaging (SPRI) system without further significant modification. Dielectrophoretic trapping and electro-osmotic displacement of the targets in the scanned fluid are performed through interdigitated 200 μm wide gold electrodes that also act as the SPR-sensing substrate. We demonstrate the efficiency of our device's collection capabilities for objects of different sizes (200 nm and 1 μm PS beads, as well as 5-10 μm yeast cells). SPRI is relevant for the spatial analysis of the mass accumulation at the electrode surface. We demonstrate that our device overcomes the diffusion limit encountered in classical SPR sensors thanks to rapid collection capabilities (<1 min) and we show a consequent improvement of the detection limit, by a factor >300. This study of an original device combining SPRI and electrokinetic forces paves the way to the development of fully integrated active plasmonic sensors with direct applications in life sciences, electrochemistry, environmental monitoring and agri-food industry.
More Related Videos
Related Concept Videos
Combined Effects of Drugs: Synergism
Such synergistic combinations...
Combined Effects of Drugs: Antagonism
The most common type is receptor antagonism, where one drug acts as an antagonist to block the effects of another drug by...
AC Sources
Resistor in an AC Circuit
One-way current through the meter is measured using diodes. A diode is a device with better conductivity in one direction compared to the other; in its ideal state, it has zero resistance in one direction and allows...
Power in an AC Circuit
In a DC circuit, there is no sinusoidal waveform associated with the supply; the voltages and currents are...
RMS Value in AC Circuit
Mathematically, the RMS value of an AC waveform is the square root...