Related Experiment Video
Updated: Jan 28, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Post-occlusional hyperemia for fractional flow reserve assessment and pull-back curve analysis
T Hirata1, T Tanigaki1, Y Kawase2
1Department of Cardiovascular Medicine, Gifu Heart Center, 4-14-4 Yabutaminami, Gifu city, 5008384, Gifu, Japan.
Abstract:
Balloon occlusion is a potential method for inducing hyperemia to measure post-percutaneous coronary intervention (PCI) fractional flow reserve (FFR). The objective of this study was to determine the clinical usefulness of post-occlusional hyperemia. FFRs measured using post-occlusional hyperemia caused by 30 (FFRoccl30) and 60 s (FFRoccl60) of balloon occlusion after PCI were compared in 60 lesions from 60 patients. The duration of hyperemia was also measured. There was a strong correlation between FFRoccl30 and FFRoccl60 (r = 0.969, p < 0.01). The duration of hyperemia was significantly longer with FFRoccl60 than with FFRoccl30 (68 ± 23 vs. 37 ± 15 s, p < 0.01). The time required for pullback curve analysis was around 45 s. However, in 7 (12%) cases, the duration of hyperemia with FFRoccl60 was < 45 s, which was not enough for pull-back curve analysis. To predict the duration of hyperemia with FFRoccl60 ≥ 45 s, the receiver operating characteristic curve analysis revealed a cut-off value of 25 s of hyperemia with FFRoccl30. FFRoccl30 is sufficient for diagnostic purposes. FFRoccl60 is suitable for pull-back curve analysis in select cases based on predictions made using the duration of hyperemia with FFRoccl30.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
05:07Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
Related Concept Videos
Precipitation Titration Curve: Analysis
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Sieve Analysis and Grading Curves
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of...
Partial Fractions