Related Experiment Video
Updated: Jan 28, 2026

Single Plane Illumination Module and Micro-capillary Approach for a Wide-field Microscope
Published on: August 15, 2014
Acoustic Field Characterization of Medical Array Transducers Based on Unfocused Transmits and Single-Plane Hydrophone
Torben Marhenke1,2, Sergio J Sanabria3,4, Bhaskara Rao Chintada5
1Computer-Assisted Applications in Medicine, ETH Zurich, 8092 Zurich, Switzerland. marhenke@ids.uni-hannover.de.
Abstract:
Medical ultrasonic arrays are typically characterized in controlled water baths using measurements by a hydrophone, which can be translated with a positioning stage. Characterization of 3D acoustic fields conventionally requires measurements at each spatial location, which is tedious and time-consuming, and may be prohibitive given limitations of experimental setup (e.g., the bath and stage) and measurement equipment (i.e., the hydrophone). Moreover, with the development of new ultrasound sequences and modalities, multiple measurements are often required to characterize each imaging mode to ensure performance and clinical safety. Acoustic holography allows efficient characterization of source transducer fields based on single plane measurements. In this work, we explore the applicability of a re-radiation method based on the Rayleigh⁻Sommerfeld integral to medical imaging array characterization. We show that source fields can be reconstructed at single crystal level at wavelength resolution, based on far-field measurements. This is herein presented for three practical application scenarios: for identifying faulty transducer elements; for characterizing acoustic safety parameters in focused ultrasound sequences from 2D planar measurements; and for estimating arbitrary focused fields based on calibration from an unfocused sound field and software beamforming. The results experimentally show that the acquired pressure fields closely match those estimated using our technique.
More Related Videos
Related Concept Videos
Plastic Deformations of Members with a Single Plane of Symmetry
Sexually Transmitted Infections
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Body Planes
The sagittal plane is the plane that divides the body or an organ vertically into right and left sides. If this vertical plane runs directly down the middle of the body resulting in equal division, it is called the midsagittal or median...
Coordinate Plane
Inhaled Medications